A dual-fuel (hybrid) system uses a heat pump when it is the cheaper source and switches to a gas or propane furnace below a set outdoor temperature. That changeover point is the practical way to get heat-pump savings without relying on electric-resistance backup in a cold snap.

Where to set the changeover

The useful rule is: switch to the furnace when the heat pump’s live COP would fall below your break-even COP at today’s prices. In mild weather the heat pump runs; in deep cold the furnace takes the load. A thermostat or control that can use outdoor temperature for that switch is what most dual-fuel setups use.

You can get the break-even COP from the gas or propane guides, or from the state price pages. If your utility offers a lower heat-pump rate, recompute with that rate — the changeover can move several degrees.

What not to do

Leaving the backup as electric-resistance strips, and setting the heat pump to give up early, is how a “heat pump” bill turns into a baseboard bill. Sizing and a realistic COP in your climate matter more than the nameplate HSPF2 alone. Convert HSPF2 only as a starting point with the HSPF2 to COP converter.

Costs this does not include

The extra equipment, a compatible thermostat, and any utility or tax credit are outside the running-cost math. The running-cost part is still worth doing first, with your own prices, in the heating cost calculator.